Specification
Insulating resistance value:
≥10MΩ @DC1000V, Maximum voltage:≥3KV
Insulating intensity:
no breakdown or arc for one minute @2500V 50Hz
Hydraulic testing pressure:
1.5 times of designed pressure
Air-tight testing pressure:
equivalent to designed pressure
Non-destructive testing:
All the butt-connectors are 100% ray-detected according to JB4730-94; other pressure welding seams are 100% magnetic power detected.
Groove:
adopt AP15L standard
Insulating material:
high strength epoxy resin and fiberglass stratification composite material
Bends intensity:
Lengthways≥390MPa Side direction≥290MPa
Pulls stretch intensity:
Lengthways≥340MPa Side direction ≥240MPa
Compressive intensity:
≥390MPa Water-absorbing≤30mg
Sacks in water behind resistance:
≥5x108Ω Breakdown resistance≥35KV
Assemblies steel:
16Mn JB4726; ASTM A694 F52 F60